state.RADXAZERO2 { control.1 { iface MIXER name 'TDMOUT_B Lane 0 Volume' value.0 0 value.1 0 comment { access 'read write' type INTEGER count 2 range '0 - 255' } } control.2 { iface MIXER name 'TDMOUT_B Lane 1 Volume' value.0 0 value.1 0 comment { access 'read write' type INTEGER count 2 range '0 - 255' } } control.3 { iface MIXER name 'TDMOUT_B Lane 2 Volume' value.0 0 value.1 0 comment { access 'read write' type INTEGER count 2 range '0 - 255' } } control.4 { iface MIXER name 'TDMOUT_B Lane 3 Volume' value.0 0 value.1 0 comment { access 'read write' type INTEGER count 2 range '0 - 255' } } control.5 { iface MIXER name 'TDMOUT_B Gain Enable Switch' value false comment { access 'read write' type BOOLEAN count 1 } } control.6 { iface PCM device 5 name 'Playback Channel Map' value.0 0 value.1 0 value.2 0 value.3 0 value.4 0 value.5 0 value.6 0 value.7 0 comment { access read type INTEGER count 8 range '0 - 36' } } control.7 { iface PCM device 5 name ELD value '100008006a100001000000000000000005e303275532374e3347365234420907070000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000' comment { access 'read volatile' type BYTES count 128 } } control.8 { iface MIXER name 'FRDDR_A SRC 1 EN Switch' value true comment { access 'read write' type BOOLEAN count 1 } } control.9 { iface MIXER name 'FRDDR_A SRC 2 EN Switch' value false comment { access 'read write' type BOOLEAN count 1 } } control.10 { iface MIXER name 'FRDDR_A SRC 3 EN Switch' value false comment { access 'read write' type BOOLEAN count 1 } } control.11 { iface MIXER name 'FRDDR_A SINK 1 SEL' value 'OUT 1' comment { access 'read write' type ENUMERATED count 1 item.0 'OUT 0' item.1 'OUT 1' item.2 'OUT 2' item.3 'OUT 3' item.4 'OUT 4' item.5 'OUT 5' item.6 'OUT 6' item.7 'OUT 7' } } control.12 { iface MIXER name 'FRDDR_A SINK 2 SEL' value 'OUT 0' comment { access 'read write' type ENUMERATED count 1 item.0 'OUT 0' item.1 'OUT 1' item.2 'OUT 2' item.3 'OUT 3' item.4 'OUT 4' item.5 'OUT 5' item.6 'OUT 6' item.7 'OUT 7' } } control.13 { iface MIXER name 'FRDDR_A SINK 3 SEL' value 'OUT 0' comment { access 'read write' type ENUMERATED count 1 item.0 'OUT 0' item.1 'OUT 1' item.2 'OUT 2' item.3 'OUT 3' item.4 'OUT 4' item.5 'OUT 5' item.6 'OUT 6' item.7 'OUT 7' } } control.14 { iface MIXER name 'FRDDR_B SRC 1 EN Switch' value true comment { access 'read write' type BOOLEAN count 1 } } control.15 { iface MIXER name 'FRDDR_B SRC 2 EN Switch' value false comment { access 'read write' type BOOLEAN count 1 } } control.16 { iface MIXER name 'FRDDR_B SRC 3 EN Switch' value false comment { access 'read write' type BOOLEAN count 1 } } control.17 { iface MIXER name 'FRDDR_B SINK 1 SEL' value 'OUT 3' comment { access 'read write' type ENUMERATED count 1 item.0 'OUT 0' item.1 'OUT 1' item.2 'OUT 2' item.3 'OUT 3' item.4 'OUT 4' item.5 'OUT 5' item.6 'OUT 6' item.7 'OUT 7' } } control.18 { iface MIXER name 'FRDDR_B SINK 2 SEL' value 'OUT 0' comment { access 'read write' type ENUMERATED count 1 item.0 'OUT 0' item.1 'OUT 1' item.2 'OUT 2' item.3 'OUT 3' item.4 'OUT 4' item.5 'OUT 5' item.6 'OUT 6' item.7 'OUT 7' } } control.19 { iface MIXER name 'FRDDR_B SINK 3 SEL' value 'OUT 0' comment { access 'read write' type ENUMERATED count 1 item.0 'OUT 0' item.1 'OUT 1' item.2 'OUT 2' item.3 'OUT 3' item.4 'OUT 4' item.5 'OUT 5' item.6 'OUT 6' item.7 'OUT 7' } } control.20 { iface MIXER name 'FRDDR_C SRC 1 EN Switch' value false comment { access 'read write' type BOOLEAN count 1 } } control.21 { iface MIXER name 'FRDDR_C SRC 2 EN Switch' value false comment { access 'read write' type BOOLEAN count 1 } } control.22 { iface MIXER name 'FRDDR_C SRC 3 EN Switch' value false comment { access 'read write' type BOOLEAN count 1 } } control.23 { iface MIXER name 'FRDDR_C SINK 1 SEL' value 'OUT 0' comment { access 'read write' type ENUMERATED count 1 item.0 'OUT 0' item.1 'OUT 1' item.2 'OUT 2' item.3 'OUT 3' item.4 'OUT 4' item.5 'OUT 5' item.6 'OUT 6' item.7 'OUT 7' } } control.24 { iface MIXER name 'FRDDR_C SINK 2 SEL' value 'OUT 0' comment { access 'read write' type ENUMERATED count 1 item.0 'OUT 0' item.1 'OUT 1' item.2 'OUT 2' item.3 'OUT 3' item.4 'OUT 4' item.5 'OUT 5' item.6 'OUT 6' item.7 'OUT 7' } } control.25 { iface MIXER name 'FRDDR_C SINK 3 SEL' value 'OUT 0' comment { access 'read write' type ENUMERATED count 1 item.0 'OUT 0' item.1 'OUT 1' item.2 'OUT 2' item.3 'OUT 3' item.4 'OUT 4' item.5 'OUT 5' item.6 'OUT 6' item.7 'OUT 7' } } control.26 { iface MIXER name 'TOHDMITX I2S SRC' value 'I2S B' comment { access 'read write' type ENUMERATED count 1 item.0 'I2S A' item.1 'I2S B' item.2 'I2S C' } } control.27 { iface MIXER name 'TOHDMITX Switch' value true comment { access 'read write' type BOOLEAN count 1 } } control.28 { iface MIXER name 'TOHDMITX SPDIF SRC' value 'SPDIF A' comment { access 'read write' type ENUMERATED count 1 item.0 'SPDIF A' item.1 'SPDIF B' } } control.29 { iface MIXER name 'TDMOUT_B SRC SEL' value 'IN 0' comment { access 'read write' type ENUMERATED count 1 item.0 'IN 0' item.1 'IN 1' item.2 'IN 2' } } }