build/packages/blobs/asound.state/asound.state.radxa-zero2

391 lines
5.9 KiB
Plaintext

state.RADXAZERO2 {
control.1 {
iface MIXER
name 'TDMOUT_B Lane 0 Volume'
value.0 0
value.1 0
comment {
access 'read write'
type INTEGER
count 2
range '0 - 255'
}
}
control.2 {
iface MIXER
name 'TDMOUT_B Lane 1 Volume'
value.0 0
value.1 0
comment {
access 'read write'
type INTEGER
count 2
range '0 - 255'
}
}
control.3 {
iface MIXER
name 'TDMOUT_B Lane 2 Volume'
value.0 0
value.1 0
comment {
access 'read write'
type INTEGER
count 2
range '0 - 255'
}
}
control.4 {
iface MIXER
name 'TDMOUT_B Lane 3 Volume'
value.0 0
value.1 0
comment {
access 'read write'
type INTEGER
count 2
range '0 - 255'
}
}
control.5 {
iface MIXER
name 'TDMOUT_B Gain Enable Switch'
value false
comment {
access 'read write'
type BOOLEAN
count 1
}
}
control.6 {
iface PCM
device 5
name 'Playback Channel Map'
value.0 0
value.1 0
value.2 0
value.3 0
value.4 0
value.5 0
value.6 0
value.7 0
comment {
access read
type INTEGER
count 8
range '0 - 36'
}
}
control.7 {
iface PCM
device 5
name ELD
value '100008006a100001000000000000000005e303275532374e3347365234420907070000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000'
comment {
access 'read volatile'
type BYTES
count 128
}
}
control.8 {
iface MIXER
name 'FRDDR_A SRC 1 EN Switch'
value true
comment {
access 'read write'
type BOOLEAN
count 1
}
}
control.9 {
iface MIXER
name 'FRDDR_A SRC 2 EN Switch'
value false
comment {
access 'read write'
type BOOLEAN
count 1
}
}
control.10 {
iface MIXER
name 'FRDDR_A SRC 3 EN Switch'
value false
comment {
access 'read write'
type BOOLEAN
count 1
}
}
control.11 {
iface MIXER
name 'FRDDR_A SINK 1 SEL'
value 'OUT 1'
comment {
access 'read write'
type ENUMERATED
count 1
item.0 'OUT 0'
item.1 'OUT 1'
item.2 'OUT 2'
item.3 'OUT 3'
item.4 'OUT 4'
item.5 'OUT 5'
item.6 'OUT 6'
item.7 'OUT 7'
}
}
control.12 {
iface MIXER
name 'FRDDR_A SINK 2 SEL'
value 'OUT 0'
comment {
access 'read write'
type ENUMERATED
count 1
item.0 'OUT 0'
item.1 'OUT 1'
item.2 'OUT 2'
item.3 'OUT 3'
item.4 'OUT 4'
item.5 'OUT 5'
item.6 'OUT 6'
item.7 'OUT 7'
}
}
control.13 {
iface MIXER
name 'FRDDR_A SINK 3 SEL'
value 'OUT 0'
comment {
access 'read write'
type ENUMERATED
count 1
item.0 'OUT 0'
item.1 'OUT 1'
item.2 'OUT 2'
item.3 'OUT 3'
item.4 'OUT 4'
item.5 'OUT 5'
item.6 'OUT 6'
item.7 'OUT 7'
}
}
control.14 {
iface MIXER
name 'FRDDR_B SRC 1 EN Switch'
value true
comment {
access 'read write'
type BOOLEAN
count 1
}
}
control.15 {
iface MIXER
name 'FRDDR_B SRC 2 EN Switch'
value false
comment {
access 'read write'
type BOOLEAN
count 1
}
}
control.16 {
iface MIXER
name 'FRDDR_B SRC 3 EN Switch'
value false
comment {
access 'read write'
type BOOLEAN
count 1
}
}
control.17 {
iface MIXER
name 'FRDDR_B SINK 1 SEL'
value 'OUT 3'
comment {
access 'read write'
type ENUMERATED
count 1
item.0 'OUT 0'
item.1 'OUT 1'
item.2 'OUT 2'
item.3 'OUT 3'
item.4 'OUT 4'
item.5 'OUT 5'
item.6 'OUT 6'
item.7 'OUT 7'
}
}
control.18 {
iface MIXER
name 'FRDDR_B SINK 2 SEL'
value 'OUT 0'
comment {
access 'read write'
type ENUMERATED
count 1
item.0 'OUT 0'
item.1 'OUT 1'
item.2 'OUT 2'
item.3 'OUT 3'
item.4 'OUT 4'
item.5 'OUT 5'
item.6 'OUT 6'
item.7 'OUT 7'
}
}
control.19 {
iface MIXER
name 'FRDDR_B SINK 3 SEL'
value 'OUT 0'
comment {
access 'read write'
type ENUMERATED
count 1
item.0 'OUT 0'
item.1 'OUT 1'
item.2 'OUT 2'
item.3 'OUT 3'
item.4 'OUT 4'
item.5 'OUT 5'
item.6 'OUT 6'
item.7 'OUT 7'
}
}
control.20 {
iface MIXER
name 'FRDDR_C SRC 1 EN Switch'
value false
comment {
access 'read write'
type BOOLEAN
count 1
}
}
control.21 {
iface MIXER
name 'FRDDR_C SRC 2 EN Switch'
value false
comment {
access 'read write'
type BOOLEAN
count 1
}
}
control.22 {
iface MIXER
name 'FRDDR_C SRC 3 EN Switch'
value false
comment {
access 'read write'
type BOOLEAN
count 1
}
}
control.23 {
iface MIXER
name 'FRDDR_C SINK 1 SEL'
value 'OUT 0'
comment {
access 'read write'
type ENUMERATED
count 1
item.0 'OUT 0'
item.1 'OUT 1'
item.2 'OUT 2'
item.3 'OUT 3'
item.4 'OUT 4'
item.5 'OUT 5'
item.6 'OUT 6'
item.7 'OUT 7'
}
}
control.24 {
iface MIXER
name 'FRDDR_C SINK 2 SEL'
value 'OUT 0'
comment {
access 'read write'
type ENUMERATED
count 1
item.0 'OUT 0'
item.1 'OUT 1'
item.2 'OUT 2'
item.3 'OUT 3'
item.4 'OUT 4'
item.5 'OUT 5'
item.6 'OUT 6'
item.7 'OUT 7'
}
}
control.25 {
iface MIXER
name 'FRDDR_C SINK 3 SEL'
value 'OUT 0'
comment {
access 'read write'
type ENUMERATED
count 1
item.0 'OUT 0'
item.1 'OUT 1'
item.2 'OUT 2'
item.3 'OUT 3'
item.4 'OUT 4'
item.5 'OUT 5'
item.6 'OUT 6'
item.7 'OUT 7'
}
}
control.26 {
iface MIXER
name 'TOHDMITX I2S SRC'
value 'I2S B'
comment {
access 'read write'
type ENUMERATED
count 1
item.0 'I2S A'
item.1 'I2S B'
item.2 'I2S C'
}
}
control.27 {
iface MIXER
name 'TOHDMITX Switch'
value true
comment {
access 'read write'
type BOOLEAN
count 1
}
}
control.28 {
iface MIXER
name 'TOHDMITX SPDIF SRC'
value 'SPDIF A'
comment {
access 'read write'
type ENUMERATED
count 1
item.0 'SPDIF A'
item.1 'SPDIF B'
}
}
control.29 {
iface MIXER
name 'TDMOUT_B SRC SEL'
value 'IN 0'
comment {
access 'read write'
type ENUMERATED
count 1
item.0 'IN 0'
item.1 'IN 1'
item.2 'IN 2'
}
}
}